Options
Voon Chun Hong
Preferred name
Voon Chun Hong
Official Name
Hong, Voon Chun
Alternative Name
Voon, C. H.
Voon, Chun Hong
Hong, Voon Chun
Hong, V. C.
Main Affiliation
Scopus Author ID
55334719400
Researcher ID
D-2050-2015
Now showing
1 - 10 of 24
-
PublicationVoltammetric DNA Biosensor for Human Papillomavirus (HPV) Strain 18 Detection( 2020-07-09)
;Mhd Akhir M.A. ; ; ; ;Rejali Z. ;Afzan A. ; ;Muhammad Nur Afnan UdaThis research was developed to focus on the study of the voltammetric DNA biosensor for the detection of HPV strain 18. In this research, electrical DNA biosensor was expected to detect HPV strain 18 more efficiently by using electrical characterization. In this project, device inspection was conducted to make sure the functional of the gold interdigitated electrode (IDE) by using Scanning Electron Microscope (SEM). 3-Aminopropyl Triethoxysilane (APTES) solution was used for the process of surface modification to form the amine group on the surface of the device to facilitate the attachment of the DNA probe. In this project, synthetic DNA sample and DNA from the saliva of several Biosystems Engineering students were used as the target DNA. The current-voltage (I-V) electrical characterization was conducted to detect the presence of HPV strain 18 in both DNA samples. As the results, perfect alignment between the electrodes on the IDE was detected under SEM. Surface modification of the biosensor successfully conducted which is the covalent bond between APTES and DNA probe increase the electrical. Synthetic DNA shows the presence of HPV strain 18 while there was no HPV strain 18 detected in the DNA from saliva samples. -
PublicationFacile electrical DNA genosensor for human papillomavirus (HPV 58) for early detection of cervical cancer( 2023-07)
;F. Nadhirah Jaapar ; ; ; ; ; ;Sh. Nadzirah ; ; ;Wei Chern Ang ;Iffah Izzati Zakaria ;Zulida Rejali ;Amilia Afzan ;Azrul Azlan Hamzah ;Chang Fu DeeF. Syakirah HalimFor decades, a Pap smear test has been applied as a conventional method in detecting Human Papillomavirus caused cervical cancer. False-positive results were also recorded while using it as conventional method. Current biosensor such as Hybrid (II) Capture resulted in higher time consumption and cost. s Meanwhile, in this study we provided facile, mini, rapid, highly sensitive, eco-friendly, and cost-effective sensing system focusing on HPV strain 58 (HPV58) in a nano-size lab-on-chip technology genosensor. 30-mer of virus ssDNA designed and analyzed as a probe via bioinformatics tools such as GenBank, Basic Local Alignment Searching Tools (BLAST) and ClustalW. Nanotechnology-developed colloidal Gold-nanoparticles (AuNPs) are used in the biosensor fabrication to produce high stability and electron efficient transmission during electrical measurement. AuNPs-APTES modified on active sites of IDEs, followed by immobilization of specific probe ssDNA for HPV 58. Hydrogen binding during hybridization with its target produce electrical signals measured by KEITHLEY 2450 (Source Meter). The genosensor validated with different types of targets such as complimentary, non-complementary and single mismatch oligonucleotides. The serial dilution of target concentration has been experimented triplicate (n=3) range from 1fM to 10μM. The slope of calibration curve resulted 2.389E-0 AM-1 with regression coefficient (R2) = 0.97535. -
PublicationFacile Electrical DNA Genosensor for Human Papillomavirus (HPV 58) for Early Detection of Cervical Cancer( 2023-07-01)
;Jaapar F.N. ; ;Halim N.H.A. ; ; ; ;Nadzirah S. ; ; ;Ang W.C. ;Zakaria I.I. ;Rejali Z. ;Afzan A. ;Hamzah A.A. ;Dee C.F.Halim F.S.For decades, a Pap smear test has been applied as a conventional method in detecting Human Papillomavirus caused cervical cancer. False-positive results were also recorded while using it as conventional method. Current biosensor such as Hybrid (II) Capture resulted in higher time consumption and cost. s Meanwhile, in this study we provided facile, mini, rapid, highly sensitive, eco-friendly, and cost-effective sensing system focusing on HPV strain 58 (HPV58) in a nano-size lab-on-chip technology genosensor. 30-mer of virus ssDNA designed and analyzed as a probe via bioinformatics tools such as GenBank, Basic Local Alignment Searching Tools (BLAST) and ClustalW. Nanotechnology-developed colloidal Gold-nanoparticles (AuNPs) are used in the biosensor fabrication to produce high stability and electron efficient transmission during electrical measurement. AuNPs-APTES modified on active sites of IDEs, followed by immobilization of specific probe ssDNA for HPV 58. Hydrogen binding during hybridization with its target produce electrical signals measured by KEITHLEY 2450 (Source Meter). The genosensor validated with different types of targets such as complimentary, non-complementary and single mismatch oligonucleotides. The serial dilution of target concentration has been experimented triplicate (n=3) range from 1fM to 10µM. The slope of calibration curve resulted 2.389E-0 AM-1 with regression coefficient (R2) = 0.97535. -
PublicationMicrowave welding with SiCNW/PMMA nanocomposite thin films: enhanced joint strength and performance(Institute of Physic, 2025-01)
;Phey Yee Foong ; ; ;Foo Wah Low ; ; ; ;Veeradasan Perumal ;Most previously reported susceptors for microwave welding are in powder form. In this study, a thin-film susceptor was employed due to its uniform heating rate and ease of handling. Silicon carbide nanowhisker (SiCNW) were incorporated into a poly(methyl methacrylate) (PMMA) matrix to create a nanocomposite thin film, which served as the susceptor. The microwave welding process involved three straightforward steps: fabrication of the PMMA/SiCNW nanocomposite thin film, application of the nanocomposite film to the target area, and subsequent microwave heating. Upon cooling, a robust microwave-welded joint was formed. The mechanical properties and microstructure of the welded joints were characterized using single-lap shear tests, three-point bending tests, and scanning electron microscopy. Results demonstrated that the shear strength and elastic modulus of the welded joints were optimized with increased heating time and SiCNW filler loading. This optimization is attributed to the formation of a SiCNW-filled polypropylene (PP) nanocomposite layer of increasing thickness at the welded joint interface. However, the incorporation of SiCNW also constrained the mobility of the PP chains, reducing the joint’s flexibility. Furthermore, the welded joint formed with the PMMA/SiCNW nanocomposite thin-film susceptor exhibited an 18.82% improvement in shear strength compared to joints formed with a powdered SiCNW susceptor. This study not only demonstrates the potential of PMMA/SiCNW nanocomposite thin films as efficient susceptors for microwave welding but also paves the way for developing high-performance polymer-based composite joints with improved mechanical properties for applications in the automotive, aerospace, and construction industries. -
PublicationElectrochemical DNA Biosensor based on 30 nM Gold Nanoparticle Modified Electrode by Electro Less Deposition for Human Papillomavirus (HPV) 18 E6 Region( 2020-07-09)
;Koo Siew Kim N.S. ;Parmin N.A. ; ; ;Rejali Z. ;Afzan A. ; ;Muhammad Nur Afnan UdaThe aim of this work was to develop a novel, simple, inexpensive, sensitive an electrochemical DNA biosensor based on interdigitated electrodes (IDEs) integrated gold nanoparticle modified electrode by electro less deposition for HPV 18. The biosensor was designed with a 30 mer E6 region of HPV 18 DNA modified probe. The E6 region has been used for their clinical importance properties and suitable as recognition biomarker region. Three different target types were tested which complementary target, non-complementary target and mismatch target. All target were analyzed for detection of HPV 18 in early stages by using Dielectric Analyzer (DA), Alpha-A High-performance Frequency Analyzer, Novocontrol Technologies, Handsagen, Germany associated with the software package Windeta. Complementary target gives a positive result in HPV detection, while non-complementary and mismatch target give negative results. IDE device with 5 nm gap sizes has demonstrated a high performance towards the detection of HPV18 ssDNA target by modified with 30 nm gold nanoparticle. The electrochemical biosensor showed better performance compared to agarose gel electrophoresis assay. This technology can be used as a new and attractive sensor development for detection of virus infection in human bodies.1 23 -
PublicationDesigning DNA probe from human Papillomavirus (HPV) 58 in E6 region as biosensing element for development of biosensor( 2024-03-21)
;Jaapar N.F. ; ;Halim N.H.A. ; ; ; ;Nadzirah S. ; ; ;Ang W.C. ;Zakaria I.I. ;Rejali Z. ;Afzan A. ;Hamzah A.A. ;Dee C.F.Halim F.S.Globally, second leading cause of death for women is a Cervical Cancer. CC is caused by infection of Human Papillomavirus (HPV). HPV strains 16 (50.8%), 18 (17.6%), and 58 (2.6%) became the most leading strains of infection in Malaysia. Recently, a study showed that HPV 58 was rare worldwide but famous in Asia countries including Malaysia. However, detection the significance of HPV-58 in women has not been studied extensively because of rare case compared to HPV 16 and 18. HPV-58 is commonly found in East Asia, but infrequently worldwide, due to changes in the environment of viruses and humans. Detailed biological knowledge is crucial for the development of effective countermeasures, diagnostic tests, vaccines and antiviral drugs against the HPV. The oligonucleotide sequences of HPV 58 in E6 region have been analysed between 24-35 mer in order to maintain the specificity and selectivity. The percentage of similarities between the coding sequences has developed with 66.7% of GC content. The DNA probe of HPV 58 was 5'GGG CGC TGT GCA GTG TGT TGG AGA CCC CGA3' with 30 mer of oligonucleotides. The important of E6 region for developing the coding sequence as it involved in the DNA reproduction, transcription, translation regulation and transformation of HPV genome. Phylogenetic trees were then constructed by Neighbour-Joining and the Kimura 2-parameters methods, followed by an analysis of selection pressures acting on the E6/E7 genes by ebi ac uk tools.20 2 -
PublicationPotentials of MicroRNA in Early Detection of Ovarian Cancer by Analytical Electrical Biosensors( 2022-01-01)
; ; ; ;Nadzirah S. ;Salimi M.N. ; ; ;Muhammad Nur Afnan Uda ;Rozi S.K.M. ;Rejali Z. ;Afzan A. ;Azan M.I.A. ;Yaakub A.R.W. ;Hamzah A.A.Dee C.F.The importance of nanotechnology in medical applications especially with biomedical sensing devices is undoubted. Several medical diagnostics have been developed by taking the advantage of nanomaterials, especially with electrical biosensors. Biosensors have been predominantly used for the quantification of different clinical biomarkers toward detection, screening, and follow-up the treatment. At present, ovarian cancer is one of the severe complications that cannot be identified until it becomes most dangerous as the advanced stage. Based on the American Cancer Society, 20% of cases involved in the detection of ovarian cancer are diagnosed at an early stage and 80% diagnosed at the later stages. The patient just has a common digestive problem and stomach ache as early symptoms and people used to ignore these symptoms. Micro ribonucleic acid (miRNA) is classified as small non-coding RNAs, their expressions change due to the association of cancer development and progression. This article reviews and discusses on the currently available strategies for the early detection of ovarian cancers using miRNA as a biomarker associated with electrical biosensors. A unique miRNA-based biomarker detections are specially highlighted with biosensor platforms to diagnose ovarian cancer.1 43 -
PublicationFormation of polypropylene nanocomposite joint using silicon carbide nanowhiskers as novel susceptor for microwave welding( 2023-05-01)
;Foong P.Y. ; ;Lim B.Y. ;Teh P.L. ; ; ; ; ;Low F.W. ;Up to present, no study has reported on the use of silicon carbide nanomaterials (SiCNMs) as susceptor for microwave welding of thermoplastics. Therefore, in this study, silicon carbide nanowhiskers (SiCNWs) was attempted as the microwave susceptor for the microwave welding of polypropylene (PP). It was observed that SiCNWs are capable of absorbing microwave and converting them into heat, leading to a sharp increase in temperature until it reaches the melting point of PP substrates. The microwave welded joint is formed after the molten PP at the interface between PP substrates is cooled under pressure. The effect of microwave heating duration and solid loading of SiCNWs suspension was studied and reported. The formation mechanism of SiCNWs reinforced PP welded joint was proposed in this study. With these remarkable advantages of microwave welding and enhanced mechanical properties of the welded joint, it is believed that this study can provide a new insight into welding of thermoplastic and material processing through short-term microwave heating.26 1 -
PublicationHydrothermal Growth Zinc Oxide Nanorods for pH Sensor Application( 2023-10-01)
; ; ; ; ; ;The aim of this work is to apply synthesized zinc oxide (ZnO) Nanorods using hydrothermal (HTL) growth technique for pH sensor application. The highly crystallite of ZnO Nanorods was obtained by anneal the growth ZnO Nanorods in furnace at 200 °C for 2 hours. Besides that, XRD analysis shows the produced ZnO Nanorods belonged to the (002) plane. Furthermore, Scanning Electron Microscope (SEM) images confirm that the ZnO Nanorods with hexagonal-faceted structural were successfully produced by HTL growth technique. In addition, Ultraviolet–visible (UV-Vis) spectrophotometer analysis shows that the synthesized ZnO belongs to the wide band gap semiconductor material. The growing ZnO Nanorods were then subjected to electrical measurement with various pH levels. The outcome demonstrates that the current rises as the solution changes from acidic to alkaline. Overall, our study shows a relationship between the electrical as well as the structural characteristics of ZnO Nanorods at various pH levels.1 -
PublicationGold-Nanohybrid Biosensors for Analyzing Blood Circulating Clinical Biomacromolecules: Current Trend toward Future Remote Digital Monitoring( 2022-01-01)
;Letchumanan I. ; ; ;Mohamed Saheed M.S. ;Perumal V. ;Mortality level is worsening the situation worldwide thru blood diseases and greatly jeopardizes the human health with poor diagnostics. Due to the lack of successful generation of early diagnosis, the survival rate is currently lower. To overcome the present hurdle, new diagnostic methods have been choreographed for blood disease biomarkers analyses with the conjunction of ultra-small ideal gold nanohybrids. Gold-hybrids hold varieties of unique features, such as high biocompatibility, increased surface-to-volume ratio, less-toxicity, ease in electron transfer and have a greater localized surface plasmon resonance. Gold-nanocomposites can be physically hybrid on the sensor surface and functionalize with the biomolecules using appropriate chemical conjugations. Revolutionizing biosensor platform can be prominently linked for the nanocomposite applications in the current research on medical diagnosis. This review encloses the new developments in diagnosing blood biomarkers by utilizing the gold-nanohybrids. Further, the current state-of-the-art and the future envision with digital monitoring for facile telediagnosis were narrated.25 2