    Analysis on silica and graphene nanomaterials obtained from rice straw for antimicrobial potential
    This study focuses on the encapsulation of silica and graphene nanoparticles and their potential applications. The encapsulation enhances the properties and effectiveness of these nanoparticles, with silica providing stability and graphene contributing to high surface area and electrical conductivity. Characterization of silica-graphene nanoparticles was conducted using various techniques including High Power Microscope (HPM), Scanning Electron Microscope (SEM), Energy-dispersive X-ray spectroscopy (EDS), and 3D Nano Profiler. The antimicrobial activity of silica, graphene, and silica-graphene nanoparticles was evaluated using a disc diffusion assay against E. coli and B. subtilis at varying concentrations. Results showed significant antimicrobial activity, with the inhibition zone being directly proportional to the concentration. Silica-graphene nanoparticles demonstrated higher efficacy against E. coli compared to B. subtilis, attributed to differences in cell wall structure. Statistical analysis using ANOVA confirmed significant differences in antimicrobial activity among the tested components.
  • Publication
    Aluminium interdigitated electrode with 5.0 μm gap for electrolytic scooting
    ( 2024-06) ; ; ; ;
    Ismail Saad
    ;
    ; ; ;
    G. Yashni
    ;
    Nur Hulwani Ibrahim
    ;
    N. Parimon
    ;
    M. F. H. Rani
    The goal of the research project is to design, fabricate, and characterize an extremely sensitive biosensor for use in healthcare. Using AutoCAD software, a novel IDE pattern with a 5 μm finger gap was created. Conventional photolithography and regular CMOS technology were used in the fabrication process. A 3D nano profiler, scanning electron microscopy (SEM), high-power microscopy (HPM), and low-power microscopy (LPM) were used to physically characterize the manufactured IDE. Chemical testing was done using several pH buffer solutions, and electrical validation was performed using I-V measurements. The Al IDE was produced, with a tolerance of 0.1 μm between the fabricated IDEs and the design mask. Electrical measurements verified the flawless fabrication of the IDE, and the device's repeatability was validated by the outcomes of comparable IDE samples. For each pH buffer solution, a modest additional volume of 2 μl was used to quantitatively detect slight current fluctuations in the microampere range. Through pH calibration for advanced applications in the realm of chemical sensors using an amperometric method, this research study has verified the chemical behavior of the IDE.