Now showing 1 - 6 of 6
  • Publication
    Electrical Capacitance Tomography (ECT) Electrode Size Simulation Study for Cultured Cell
    ( 2021-11-25)
    Zulkiflli N.A.
    ;
    Shahrulnizahani M.D.
    ;
    Hor X.F.
    ;
    Phang F.A.
    ;
    Rahmat M.F.
    ;
    Khang A.W.Y.
    ;
    ;
    Mohamed R.
    ;
    Leow P.L.
    ;
    Pusppanathan J.
    Cell sensing and monitoring using capacitive sensors are widely used in cell monitoring because of the flexible and uncomplicated design and fabrication. Previous work from many different fields of applications has integrated capacitive sensing technique with tomography to produce cross-sectional images of the internal dielectric distribution. This paper carried an investigation on the capabilities of four 16-channel sensor electrodes with different electrode sizes to detect the change in the dielectric distribution of the cultured cells. All three 16-channel sensor electrodes are designed and simulate on COMSOL 6.3a Multiphysics. The pre-processing results obtained from three finite element models (FEM) of ECT sensor configurations in detecting the cell phantom shows that bigger electrodes size are more sensitive to permittivity distribution.
      1
  • Publication
    Single Channel Magnetic Induction Measurement for Meningitis Detection
    ( 2021-01-01)
    Aiman Abdulrahman Ahmed
    ;
    ;
    Ali M.H.
    ;
    Pusppanathan J.
    ;
    Rahim R.A.
    ;
    Muji S.Z.M.
    ;
    ; ; ; ;
    Ahmad Faizal Salleh
    Bacterial meningitis is one of the most common and prominent infections which infects the central nervous system through the tissue layers and membranes that cover our brain and spinal cord. It is a staggering and fatal illness that kills patients within hours. The number of meningitis cases that has been recorded annually around the world are one million cases and 135,000 deaths. Early detection and start of sufficient treatment are considered as the main determinants for better result. MIT mechanism is noncontact electrodes of impedance measurement. This mechanism uses induction principle instead of contact electrodes to get the required information. This paper presents an overview on the potential of Magnetic induction tomography (MIT) in detecting meningitis disease. In MIT principle, single channel measurement process which consist of transmitter (Tx) and receiver (Rx) coil has been studied. In this field is disclosed about passive electrical field (PEP) which focuses on the three parameters which are dielectric permittivity, electrical conductivity, and magnetic permeability. In addition, this research project involves experimental setup. The applied frequency is between 1–10 MHz. Finally, in this project, the performance of the square coil with 12 number of turns (5Tx–12Rx) with 10 MHz frequency has been identified as the suitable transmitter-receiver pair and the optimum frequency for detecting the conductivity property distribution of brain tissues.
      1
  • Publication
    Simulation of Single Channel Magnetic Induction Tomography for Meningitis Detection by Using COMSOL Multiphysics
    ( 2021-11-25)
    Aiman Abdulrahman Ahmed
    ;
    ;
    Ali M.H.
    ;
    ;
    Siti Fatimah Abdul Halim
    ;
    ;
    Pusppanathan J.
    ;
    Rahim R.A.
    Meningitis is a inflammation of the meninges and the most common central nervous system (CNS) due to bacterial infection. Numbers of children who have bacterial meningitis are still high in recent 15 years regardless of the availability of newer antibiotics and preventive strategies. This research focuses on simulation using COMSOL Multiphysics on the design and development of magnetic induction tomography (MIT) system that emphasizes on a single channel rotatable of brain tissue imaging. The purpose of this simulation is to test the capability of the developed MIT system in detecting the change in conductivity and to identify the suitable transmitter-receiver pair and the optimum frequency based on phase shift measurement technique for detecting the conductivity property distribution of brain tissues. The obtained result verified that the performance of the square coil with 12 number of turns (5Tx-12Rx) with 10MHz frequency has been identified as the suitable transmitter-receiver pair and the optimum frequency for detecting the conductivity property distribution of brain tissues.
      1
  • Publication
    Initial Results on Primary Field Cancellation of Magnetic Induction Spectroscopy Technique for Fetal Acidosis Detection using COMSOL Multiphysics
    ( 2021-11-25)
    Siti Fatimah Abdul Halim
    ;
    ; ; ; ;
    Ahmed A.A.
    ;
    Pusppanathan J.
    ;
    ;
    Muji S.Z.M.
    ;
    Rahim R.A.
    Monitoring of fetal condition during labor could save hundred lives in a single year. During labor, fetus is at critical condition as acidosis may occur suddenly without any early symptoms. Invasive method such as Fetal Blood Sampling (FBS) has been used to detect the decline in pH level of fetus. However, fetal loss rate after FBS may range from 1.4% up to 25%. In this paper, magnetic field induction spectroscopy was implemented to determine fetal acidosis by using primary magnetic field cancellation technique. Magnetic Induction Spectroscopy (MIS) probe was design where transmitter coil (TX) is perpendicular to receiver coil (RX). The result shows that the secondary magnetic field produced have been successfully measured without any interruption from primary magnetic field. By using transmitter input 1A, it shows that voltage is inversely proportional to the blood pH due to the conductivity properties of blood.
      1
  • Publication
    A Review on Magnetic Induction Spectroscopy potential for fetal acidosis examination
    Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have caused serious injury to the fetus, especially for the brain and the heart. This paper reviews the new technique in diagnosis of acidosis non-invasively. Magnetic Induction Spectroscopy (MIS) has been proposed to be a new device for acidosis detection in recent years. This paper explains the basic principle of MIS and outlines the design specifications and design considerations for a MIS pH probe. It is expected that readers will gain a basic understanding of the development of a MIS pH probe from this review.
      3
  • Publication
    An Overview of Medical Applications in Meningitis Detection
    ( 2020-07-09)
    Abdulrahman Ahmed A.
    ;
    ;
    Hamood Ali M.
    ;
    Pusppanathan J.
    ;
    Zarina Mohd Mhji S.
    ;
    ; ; ; ;
    Meningitis remains one of the common infections among young children with high morbidity and mortality rates. In Southeast Asian, only few studies were reported published which evaluated meningitis clinically in the last two decades. Similarly, few studies in Malaysia evaluated meningitis among adolescents and children. Globally, more than one million cases with 135,000 deaths has been recorded yearly, and in Malaysia, severe neurological complications occurs in 9-25% of cases which affirms the most serious risk manifests from bacterial meningitis. Therefore, early detection and effective treatment are required before the irreversible damages occur. This paper reviews the current states and perspectives of diagnostic techniques on meningitis detection. Currently, there are three diagnostic techniques available for meningitis detection, such as blood cultures, spinal tap (lumbar puncture), and imaging techniques (CT scan, MRI, EIT, Ultrasonography, Nuclear imaging and X-ray). However, these techniques have limitations that may limit the chances of carrying out the early detection of the disease. The essence of this review is that meningitis requires an effective technique that is capable of carrying out the early detection of the disease by differentiating normal people and Meningitis infected patients so as to promote longevity worldwide. In this review magnetic induction tomography (MIT) technique is proposed to diagnose meningitis earlier as it is non-intrusive, non-invasive, contactless, and electrode-less imaging technique which does not expose the patients to a harmful radiation.
      1