Now showing 1 - 4 of 4
  • Publication
    Improvement of Dissolved Oxygen in Perlis River based on Various Aeration Systems
    ( 2021-12-14)
    Muhammad Faiz Hilmi Rani
    ;
    ; ; ; ; ; ; ;
    Ibrahim Z.
    ;
    ;
    Mohamad Aniq Syazwan Mohamed Hassan
    ;
    Abd Manap A.A.
    ;
    Zainuddin I.F.
    Water pollution is closely related to the Water Quality Index (WQI). One of the parameters in classifying WQI is dissolved oxygen (DO) that can be improved by introducing the surface and subsurface aerations. Herein, the Perlis River's water quality was investigated by evaluating the DO's improvement based on various aeration systems. The changes of DO (mg/L) and DO improvement (%) were evaluated during both low and high tide conditions. A total of 9 sets of data collection had been studied by comparing base DO (without running of aeration) and measured DO (with running of aeration) of river. The DO sensor was used to measure the changes of DO in the aeration measurement system. Results found that the DO improvement managed to achieve 74.89%, 10.18%, 35.58%, and 52.45% for water jet, air compressor, commercial venturi, and DIY venturi, respectively. Besides, different behaviour of DO's improvement was observed during low and high tide conditions.
      5  42
  • Publication
    Derivation and validation of heat transfer model for Spark-Ignition engine cylinder head
    The valve train is located in the engine cylinder head, which has various operational heat transfer mechanisms to accommodate the combustion process. Most heat transfer studies in this area have only addressed medium-to high-power vehicles at a single running speed. In this study, a model of an air-cooled underbone motorcycle valve, valve seat, and engine cylinder head was tested to determine the thermal characteristics using actual engine operating conditions at low, medium, and high engine speeds. One-dimensional thermal simulation analyses were conducted to obtain the instantaneous heat-transfer coefficients of an actual engine. The average thermal value was determined as the boundary condition in the three-dimensional thermal analysis. A three-dimensional model was prepared using the ANSYS commercial computational fluid dynamics software package. The results show that as the engine speed increases, so does the thermal load toward the component in the engine cylinder head. The strongest temperature regions were concentrated around the combustion face. The exhaust valve held most of the heat, with the valve neck recording the highest temperature. For the intake valve, the combustion face registered the majority of the heat. The heat flux intensity was gathered in the contact surface area between the valve and its seat, between the valve stem and guide, and between the stem guide and tip section. A thermal survey was used to validate the three modelling results for two separate engine datasets. The cumulative relative errors for intake and exhaust valve seats for low engine speeds were 3.73% and 0.17%, respectively. The intake and exhaust valve seats had cumulative relative errors of 4.12% and 0.70%, respectively, at intermediate speeds. This methodology provides valuable information for analysing the heat characterisation of air-cooled engines. It can also be a useful blueprint for the automotive industry and other researchers involved in thermal measurements.
      32  2
  • Publication
    CFD Simulation on Improving Water Quality based on Various Aerator Models to Demonstrate Cost Performance Analysis
    ( 2021-12-14)
    Nazrul Najmi Norbashah
    ;
    Muhammad Faiz Hilmi Rani
    ;
    ; ; ; ; ; ; ;
    Ibrahim Z.
    ;
    ;
    Mohamad Aniq Syazwan Mohamed Hassan
    ;
    Abd Manap A.A.
    ;
    Zainuddin I.F.
    There are many types of aerator that can be used to perform a water treatment process either from air to water or from water to air approaches. Other than focusing on the performance itself, the usage cost of aerator should be forecasted in detail too to have a sustainable and economical method in remediating the polluted water. Therein, the cost performance analysis was demonstrated by performing a computational fluid dynamics (CFD) simulation on improving water quality based on various aerator models. The simulation was focused in a small-scale aeration tank that consists of a mixing chamber, air duct, and a few of bubble diffusers. The improvement of water quality was assessed by calculating the number of gas bubble particles produced by 4 different configurations of aerator model, namely aerator model A, B, C and D, respectively. Results found that the aerator model D (5 bubble diffuser at 620 L/min) produces the highest number of gas particles up to 72.2%. However, the aerator model C (5 bubble diffuser at 300 L/min) was found to achieve the most efficient and sustainable approach based on energy consuming and cost of aerator configuration when compared to the other aerator models.
      3  37
  • Publication
    Development of a Novel Aeration Measurement System to Evaluate Water Treatment Process in a River
    ( 2021-12-14)
    Muhammad Faiz Hilmi Rani
    ;
    ; ; ; ; ; ; ;
    Ibrahim Z.
    ;
    ;
    Mohamad Aniq Syazwan Mohamed Hassan
    ;
    Abd Manap A.A.
    ;
    Zainuddin I.F.
    A novel aeration measurement system was developed to evaluate the water treatment process in a river to acquire a more comparable dissolved oxygen value even if various types of aerations are tested. The system comprises of DO sensor, water flowmeter, anemometer, PVC pipes, water pump, air compressor pump, and truck tyre tubes. The PVC pipes consisting of a main drainage hole, 5 holes for dissolve oxygen data collection, 1 hole as the location of aerator system, and connectors were designed as the major part of the system by using Computer Aided Design software. The main drainage hole (horizontal pipe) was designed to be 288.5 cm in length, while the measured holes (vertical pipes) were designed to be 45.7 cm in height. By considering a systematic approach, the designed system is hopefully able to solve measuring issue of dissolved oxygen in moving water and to provide a better evaluation of water treatment process.
      1  34