Options
Zarimawaty Zailan
Preferred name
Zarimawaty Zailan
Official Name
Zarimawaty, Zailan
Alternative Name
Zailan, Z.
Zailan, Zarimawaty
Main Affiliation
Scopus Author ID
55603553500
Researcher ID
EHB-9502-2022
Now showing
1 - 4 of 4
-
PublicationSilicon nanowire biosensors for diabetes mellitus monitoring( 2024-10)
;M. Shaifullah A. S ;J. Jumat ;J. N. Ismail ;M. SyamsulRozaimah A. TThe main goal of this research is the development of a label-free biosensor for the detection of diabetes mellitus (DM) using the target molecule retinol-binding protein 4 (RBP4). The enzyme-linked immunosorbent assay (ELISA) approach, currently used to detect DM, is time-consuming and difficult. As a result, label-free biosensors are being considered as an alternative. In this research, silicon nanowires (SiNWs) were selected as the transducer for this biosensor due to their low cost, real-time analysis capability, high sensitivity, and low detection limit. The SiNWs were created using conventional lithography, reactive ion etching (RIE), and physical vapor deposition (PVD), and then dripped with a gold nanoparticle solution to create gold-decorated SiNWs. The surface of the gold-decorated SiNWs was functionalized using 3-aminothiophenol and glutaraldehyde solutions before being immobilized with DM RBP4 antibodies and targets. The electrical characterization of the gold nanoparticle decorated SiNWs biosensor revealed good performance in DM detection. The pH tests confirmed that the SiNWs acted as a transducer, with current proportional to the DM RBP4 concentration. The estimated limit of detection (LOD) and sensitivity for detecting DM RBP4 binding were 0.076 fg/mL and 8.92 nA(g/mL)-1, respectively. This gold nanoparticle decorated SiNWs biosensor performed better than other methods and enabled efficient, accurate, and direct detection of DM. The SiNWs could be used as a distinctive electrical protein biosensor for biological diagnostic purposes. In conclusion, gold nanoparticle deposition offers effective label-free, direct, and high-accuracy DM detection, outperforming previous approaches. Thus, these SiNWs serve as novel electrical protein biosensors for future biological diagnostic applications. -
PublicationFabrication and simulation of silicon nanowire pH sensor for Diabetes Mellitus detection( 2023-04)
;C. Y. Chean ;M. I. HashimRozaimah A.TDiabetes Mellitus (DM) is a disease failed to control the balance of blood sugar level due to lack of insulin thereby it effect human health. In Malaysia, there are around 3.9 millions people aged 18 years old and above have diabetes according to National Health and Morbidity Survey 2019. Silicon Nanowire is a nanostructure which has ultra-high sensitivity and non-radioactive that has potential given good performances when applied on pH sensor and biosensor. Silicon nanowire pH sensor and biosensor is an electronic sensor that investigated to improve the sensitivity and accuracy for detecting DM. This project consists of two parts, which are fabrication of silicon nanowire pH sensor and simulation of silicon nanowire biosensor as preliminary study. In fabrication, silicon nanowire of pH sensor is fabricated by conventional lithography process, reaction ion etching (RIE) and metallization to achieved the width of 100 nm silicon nanowire. The pH6, pH7, pH10 and DI water as analytes to analysis the current-voltage (I-V) characteristics of silicon nanowire pH sensor. In second part, the silicon nanowire biosensor as preliminary study is done simulation by Silvaco ATLAS devices simulator. The silicon nanowire with 30 nm in height and 20 nm in width of biosensor is designed and simulated to analyze the performance in terms of sensitivity. I-V characteristics of silicon nanowire biosensor according to different concentration of negative interface charge is determined. The negative interface charge represent as the Retinol Binding Protein 4 (RBP4) which is used to diagnose DM. The I-V characteristic based on the change in current, resistance and conductance to determine sensitivity. Lastly, the sensitivity of silicon nanowire pH sensor obtained 23.9 pS/pH while the sensitivity of simulated silicon nanowire biosensor obtained 3.91 nS/e.cm2. The results shown the more negative charge of concentration analyte attached on surface silicon nanowire has been accumulated more current flow from drain terminal to source terminal. It leads to the resistance becomes highest and obtained good sensitivity. In summary, the silicon nanowire pH sensor exhibited good performance and high sensitivity in detection pH level. The simulated silicon nanowire biosensor is capable of detecting biomolecular interactions charges to obtained high sensitive and accuracy result. -
PublicationFabrication and simulation of silicon nanogaps pH sensor as preliminary study for Retinol Binding Protein 4 (RBP4) detection( 2025-01)
;M. I. Hashim ;M. Shaifullah A.S ;C. Y. Chean ;M. SyamsulRozaimah A.T.In this research, a silicon nanogap biosensor has the potential to play a significant role in the field of biosensors for detecting Retinol Binding Protein 4 (RBP4) molecules due to its unique nanostructure morphology, biocompatibility features, and electrical capabilities. Additionally, as preliminary research for RBP4, a silicon nanogap biosensor with unique molecular gate control for pH measurement was developed. Firstly, using conventional lithography followed by the Reactive-ion etching (RIE) technique, a nanofabrication approach was utilized to produce silicon nanogaps from silicon-on-insulator (SOI) wafers. The critical aspects contributing to the process and size reduction procedures were highlighted to achieve nanometer-scale size. The resulting silicon nanogaps, ranging from 100 nm to 200 nm, were fabricated precisely on the device. Secondly, pH level detection was performed using several types of standard aqueous pH buffer solutions (pH 6, pH 7, pH 12) to test the electrical response of the device. The sensitivity of the silicon nanogap pH sensor was 7.66 pS/pH (R² = 0.97), indicating that the device has a wide range of pH detecting capacity. This also includes the silicon nanogap biosensor validated by simulation, with the sensitivity obtained being 3.24 μA/e.cm² (R² = 0.98). The simulation of the sensitivity is based on the interface charge (Qf) that represents the concentration of RBP4. The results reveal that the silicon nanogap biosensor has excellent characteristics for detecting pH levels and RBP4 with outstanding sensitivity performance. In conclusion, this silicon nanogap biosensor can be used as a new electrical RBP4 biosensor for biomedical diagnostic applications in the future. -
PublicationNanoparticle-based biosensors for detection of heavy metal ions( 2023-10)
;Y. J. Beh ;S. B. Chia ;C. H. Ng ;C. C OngHeavy metal pollution is one of the most serious environmental problems in the world. Many efforts have been made to develop biosensors for monitoring heavy metals in the environment. Development of nanoparticle-based biosensors is the most effective way to solve this problem. This review presents the latest technology of nanoparticle-based biosensors for environment monitoring to detect heavy metal ions, which are magnetic chitosan biosensor, colorimetric biosensor, and electrochemical biosensor. Magnetic chitosan biosensor acts as a nano-absorbent, which can easily detect and extract poisonous heavy metal ions such as lead ions and copper ions. There are several methods to prepare the chitosan based on the nanoparticle, which are cross-linking, co-precipitation, multi-cyanoguanidine, and covalent binding method. In colorimetric biosensor, gold and silver nanoparticles are commonly used to detect the lead and mercury ions. In addition, this biosensor is very sensitive, fast and selective to detect metal ions based on the color change of the solution mixture. Meanwhile, electrochemical biosensor is widely used to detect heavy metal ions due to a simple and rapid process, easy, convenient and inexpensive. This biosensor is focused on the surface area, which leads to significant improvement in the performance of devices in terms of sensitivity. The wide surface area can affect the performance of the biosensor due to a limited space for operation of electrode. Therefore, reduced graphene oxide is a suitable material for making the electrochemical biosensor due to a wide surface area, good conductivity and high mechanical strength. In conclusion, these three technologies have their own advantages in making a very useful biosensor in the detection of heavy metal ions.1 9