Now showing 1 - 3 of 3
  • Publication
    Multiple Partial Discharge Signal Classification Using Artificial Neural Network Technique in XLPE Power Cable
    ( 2023-02-01)
    Halim M.I.A.
    ;
    Razaly N.Z.M.
    ;
    ; ;
    Auni W.N.
    ;
    ; ; ;
    Mas’ud A.A.
    According to partial discharge (PD) damage in the electrodes that are not entirely bridging, the presence of PD in the high voltage (HV) power cable might lead to insulation failure. PD defects can damage cross-linked polyethylene (XLPE) cables directly, which is one of the most critical electrical issues in the industry. Poor workmanship during cable jointing, aging, or exposure to the surrounding environment is the most common cause of PD in HV cable systems. As a result, the location of the PD signals that occur cannot be classified without identifying the multiple PD signals present in the cable system. In this study, the artificial neural network (ANN) based feedforward back propagation classification technique is used as a diagnostic tool thru MATLAB software in which the PD signal was approached to determine the accuracy of the location PD signal. In addition, statistical feature extraction was added to compare the accuracy of classification with the standard method. The three-point technique is also an approach used to locate PD signals in a single line 11 kV XLPE underground power cable. The results show that the statistical feature extraction had been successful classify the PD signal location with the accuracy of 80% compared to without statistical feature extraction. The distance between PD signals and the PD source affected the result of the three-point technique which proved that a lower error means a near distance between them.
  • Publication
    A review: Partial discharge detection using acoustic sensor on high voltage transformer
    Partial discharge (PD) is an electrical discharge which is one of the most critical breakdown factor that is affecting the electrical equipment. The loss of the power will affect consumers and system operation. High voltage (HV) transformer is one of the equipment's subjected to phenomena PD. In this paper reviews an application of acoustic methods in transformer and piezoelectric sensors application on PD detection in HV transformer. Based on this review, the new design in acoustic sensor is required in order to improve the sensitivity and bandwidth for PD detection at HV transformer. The valuable parameter such as materials, size, and PD frequency range were discussed in this paper and can be used for early stage on designing new acoustic sensor. This detection method given some benefits on preventing the power electrical system from breakdown.
  • Publication
    Analysis on Multiple Acoustic and Electrical Emission of PD Signal Based on Signal to Noise Ratio (SNR) on Power Cable
    ( 2020-12-11)
    Mohammad W.N.A.W.
    ;
    ; ; ; ;
    Abdullah A.Z.
    ;
    Jamil M.K.M.
    Acoustic Emission (AE) and Electrical Emission (EE) partial discharge (PD) monitoring are effective methods in detection of the insulation failure in power cables. However, the unwanted noise from the surrounding environment can influence the effectiveness and accuracy of the PD measurement on the PD signal. Therefore, Discrete Wavelet Transform (DWT) denoising technique is introduced in order to suppress the disrupted noise. In this study, a different type of mother wavelet, level decomposition and its frequency spectrum on multiple AE and EE PD signals were performed via MATLAB software in order to analyze the performance of denoising technique. These PD signals were deal with white noise and Discrete spectral interference (DWT). The better performance of denoising technique is based on evaluating the maximum value of Signal to Noise Ratio (SNR) in order to find the optimum mother wavelet. In this case, the most optimum mother wavelets are rbio3.3 for AE and EE PD signals respectively with the highest value of SNR.