  5. Assessment on the performance of flat slab under service load and ultimate load using ABAQUS
 
Options

Assessment on the performance of flat slab under service load and ultimate load using ABAQUS

Journal
IOP Conference Series: Earth and Environmental Science
ISSN
17551307
Date Issued
2020-06-10
Author(s)
Shamshinar Salehuddin
Universiti Malaysia Perlis
Zaini S.S.
Universiti Sains Malaysia
Nik Zainab Nik Azizan
Universiti Malaysia Perlis
Nur Liza Rahim
Universiti Malaysia Perlis
Norlia Mohamad Ibrahim
Universiti Malaysia Perlis
Mustaqqim Abdul Rahim
Universiti Malaysia Perlis
Asyraf Mamat Ghani
Universiti Malaysia Perlis
DOI
10.1088/1755-1315/476/1/012059
Abstract
The research carried out to study on the performance of the flat slab under the design load. The design loads consist of service load, 14.68 kN/m2 and the ultimate load, 21.31 kN/m2. The justification on the design load was from the car park. The Three-Dimensional (3D) Finite Element Analysis (FEA) were conducted to investigate their failures modes with the appropriate modelling of element, mesh and concrete parameter. The size of flat slab was 1200 mm x 1200 mm x 175 mm while the material parameters were the Grade 25 for concrete and S275 for steel. It is found that the improvements more than 20% to the strength of model flat slab with shear reinforcement. Another outcome of the study indicated that the punching shear location using the FEA was less than 250 mm from column perimeter which is within the two times the depth (2d) from column face as proposed by the Eurocode 2: Design of Concrete Structures.