Publication:
Blood biomarkers diagnosis as primitive precautionary using zinc oxide (ZnO) modified interdigitated electrode (IDE)
Blood biomarkers diagnosis as primitive precautionary using zinc oxide (ZnO) modified interdigitated electrode (IDE)
| cris.author.scopus-author-id | 57205627473 | |
| cris.author.scopus-author-id | 57211870224 | |
| cris.author.scopus-author-id | 7006558013 | |
| cris.author.scopus-author-id | 57207772172 | |
| cris.author.scopus-author-id | 57214085865 | |
| dc.contributor.author | Letchumanan I. | |
| dc.contributor.author | Md Arshad M.K. | |
| dc.contributor.author | Gopinath S.C.B. | |
| dc.contributor.author | Dalila R. N. | |
| dc.contributor.author | Wan Amirah Basyarah Z.A. | |
| dc.date.accessioned | 2024-12-14T08:06:58Z | |
| dc.date.available | 2024-12-14T08:06:58Z | |
| dc.date.issued | 2019-07-01 | |
| dc.description.abstract | This paper primarily demonstrates the detection of human blood biomarkers by evaluating the binding event between antigen and antibody. An interdigitated electrode (IDE) was utilized in this work with the bandgap ~100 µm which was modified with antibody (probe) to capture available antigen. Surface analysis was done by atomic force microscope(AFM), scanning electron microscope (SEM) and 3D Nano Profilometer. The electrical measurements was done using linear sweep 0V to 2V. The sensitivity attained was 100 fM. | |
| dc.identifier.doi | 10.1109/SENSORSNANO44414.2019.8940089 | |
| dc.identifier.isbn | [9781538656198] | |
| dc.identifier.scopus | 2-s2.0-85078108097 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14170/11117 | |
| dc.relation.funding | Ministry of Higher Education, Malaysia | |
| dc.relation.grantno | undefined | |
| dc.relation.ispartof | 2019 IEEE International Conference on Sensors and Nanotechnology, SENSORS and NANO 2019 | |
| dc.relation.ispartofseries | 2019 IEEE International Conference on Sensors and Nanotechnology, SENSORS and NANO 2019 | |
| dc.subject | Aluminium interdigitated electrodes | Blood biomarkers | |
| dc.title | Blood biomarkers diagnosis as primitive precautionary using zinc oxide (ZnO) modified interdigitated electrode (IDE) | |
| dc.type | Conference Proceeding | |
| dspace.entity.type | Publication | |
| oairecerif.affiliation.orgunit | Universiti Malaysia Perlis | |
| oairecerif.affiliation.orgunit | Universiti Malaysia Perlis | |
| oairecerif.affiliation.orgunit | Universiti Malaysia Perlis | |
| oairecerif.affiliation.orgunit | Universiti Malaysia Perlis | |
| oairecerif.affiliation.orgunit | Universiti Malaysia Perlis | |
| oairecerif.citation.number | 8940089 | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.scopus-author-id | 57205627473 | |
| person.identifier.scopus-author-id | 57211870224 | |
| person.identifier.scopus-author-id | 7006558013 | |
| person.identifier.scopus-author-id | 57207772172 | |
| person.identifier.scopus-author-id | 57214085865 |