Publication:
Improving Indoor Environmental Quality (IEQ) and comfortability of lecture rooms: case study – UniCITI Alam Campus, Padang Besar, Malaysia

cris.virtual.department Universiti Malaysia Perlis
cris.virtualsource.department 8bdb7aa5-caf0-45e1-9703-50ff9d29f1e3
dc.contributor.author Nurul Akmam Naamandadin
dc.contributor.author Siti Nur Aishah Mohd Noor
dc.contributor.author Norrazman Zaiha Zainol
dc.contributor.author Arita Hanim Awang
dc.contributor.author Syakir Amir Abdul Rahman
dc.contributor.author Khairunnisa Mohamad
dc.contributor.author Muhammad Naim Ahmad
dc.date.accessioned 2025-11-10T04:23:37Z
dc.date.available 2025-11-10T04:23:37Z
dc.date.issued 2020
dc.description.abstract UniCITI Alam is a mixed development of commercial buildings and medium rise apartments. The whole development was designed based on the integration of student residential community with the combined commercial centre and temporary campus. The lecture rooms are located at the second floor of the triple-storey shop house. To improve the indoor environmental quality and comfortability of the teaching and learning activities, physical measurements of the indoor environment parameters (air temperature, relative humidity and carbon dioxide (CO2) concentration) and light intensity are the main methods applied in the presented case study. Data collected will be compared with Malaysian Standard MS 1525: 2007 (Code of Practice on Energy Efficiency and Use of Renewable for Non Residential Building) and DOSH. The finding will be used for improving the environmental quality of the lecture rooms and enhancing the ecology circle.
dc.identifier.doi 10.1088/1757-899X/743/1/012027
dc.identifier.uri https://iopscience.iop.org/
dc.identifier.uri https://iopscience.iop.org/article/10.1088/1757-899X/743/1/012027
dc.identifier.uri https://hdl.handle.net/20.500.14170/15019
dc.language.iso en
dc.publisher IOP Publishing
dc.relation.conference 1st International Conference Functional and Engineering Materials (FEM 2019), Lodz, Poland
dc.relation.ispartof IOP Conference Series
dc.relation.ispartofseries Materials Science and Engineering
dc.relation.issn 1757-8981
dc.relation.issn 1757-899X
dc.title Improving Indoor Environmental Quality (IEQ) and comfortability of lecture rooms: case study – UniCITI Alam Campus, Padang Besar, Malaysia
dc.type Resource Types::text::conference output::conference proceedings
dspace.entity.type Publication
oaire.citation.endPage 6
oaire.citation.issue 1
oaire.citation.startPage 1
oaire.citation.volume 743
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation International Islamic University Malaysia
oairecerif.author.affiliation International Islamic University Malaysia
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation Universiti Malaysia Perlis
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Improving Indoor Environmental Quality (IEQ) and comfortability of lecture rooms.pdf
Size:
1.59 MB
Format:
Adobe Portable Document Format
Description: