Publication:
Optimum sizing of photovoltaic powered uninterruptible power supply system

cris.author.scopus-author-id 57201887231
cris.author.scopus-author-id 57199152380
cris.author.scopus-author-id 57191954403
cris.author.scopus-author-id 57217465400
cris.author.scopus-author-id 57204889598
cris.virtual.department Universiti Malaysia Perlis
cris.virtual.department Universiti Malaysia Perlis
cris.virtualsource.department f4f866e4-9f01-43df-b0ce-cccb5f60fb26
cris.virtualsource.department 781aa337-a928-4267-a522-ca017430384e
dc.contributor.author Mahrizal Masri
dc.contributor.author Muhammad Irwanto Misrun
dc.contributor.author Hermansyah Alam
dc.contributor.author Haziah Abdul Hamid
dc.contributor.author Butar-Butar A.H.
dc.date.accessioned 2025-01-13T13:26:37Z
dc.date.available 2025-01-13T13:26:37Z
dc.date.issued 2017-10-01
dc.description.abstract Inverters installed in the photovoltaic (PV) powered uninterruptible power supply (UPS) system consist of battery and also PV module. An optimum number of PV module and battery should be considered to reduce costs and technical works. The PV powered UPS system is operated directly by the PV module, therefore, an optimization sizing of PV powered UPS system should be studied in terms of optimum PV module number that related to the power capacity of PV powered UPS system, solar radiation and temperature. This paper presents an optimum sizing of PV powered UPS system application. A mathematical modeling is created to obtain the optimum number of PV module and battery. The result shows that for 12V, 100W PV powered UPS system applying the 60W, 21V PV module, 12V, 100Ah battery, 700W AC load power, thus, the optimum number of PV module and battery are 20 modules and 5 pieces, respectively.
dc.identifier.doi 10.17654/EC017051111
dc.identifier.scopus 2-s2.0-85057642194
dc.identifier.uri https://hdl.handle.net/20.500.14170/13078
dc.language.iso en
dc.relation.grantno undefined
dc.relation.ispartof Far East Journal of Electronics and Communications
dc.relation.ispartofseries Far East Journal of Electronics and Communications
dc.relation.issn 09737006
dc.subject UPS
dc.subject Optimum sizing
dc.subject Photovoltaic
dc.title Optimum sizing of photovoltaic powered uninterruptible power supply system
dc.type Journal
dspace.entity.type Publication
oaire.citation.endPage 1117
oaire.citation.issue 5
oaire.citation.startPage 1111
oaire.citation.volume 17
oairecerif.affiliation.orgunit Institut Teknologi Medan
oairecerif.affiliation.orgunit Institut Teknologi Medan
oairecerif.affiliation.orgunit Institut Teknologi Medan
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.author.affiliation North Sumatra Islamic University
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation Institut Teknologi Medan
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.scopus-author-id 57201887231
person.identifier.scopus-author-id 57199152380
person.identifier.scopus-author-id 57191954403
person.identifier.scopus-author-id 57217465400
person.identifier.scopus-author-id 57204889598
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
Research repository notification.pdf
Size:
4.4 MB
Format:
Adobe Portable Document Format
Description: