Publication:
Rectifier for RF energy harvesting using stub matching
Rectifier for RF energy harvesting using stub matching
| cris.author.scopus-author-id | 26428028100 | |
| cris.author.scopus-author-id | 57210314287 | |
| cris.author.scopus-author-id | 57207882127 | |
| cris.author.scopus-author-id | 36193240000 | |
| dc.contributor.author | Adam I. | |
| dc.contributor.author | Yasin M.N.M. | |
| dc.contributor.author | Aziz M.E.A. | |
| dc.contributor.author | Sulaiman M.I. | |
| dc.date.accessioned | 2024-12-14T07:24:32Z | |
| dc.date.available | 2024-12-14T07:24:32Z | |
| dc.date.issued | 2019-03-01 | |
| dc.description.abstract | One of challenge in rectenna design is the impedance matching of the antenna to the rectifier load. Rectifier exhibits complex impedance while antennas are normally designed to match either 50 ω or 75 ω loads. For the optimum power transfer between antenna and the rectifier circuit, both impedances should be matched. This paper presents the design and development of the 7-stages Dickson multiplier in energy harvesting. The objective of this paper is to analyze the performance of the designed multiplier together with matching circuit. An improvement of 60% output voltage is achieved by feeding -30dBm of low input power at the multiplier circuit. | |
| dc.identifier.doi | 10.11591/ijeecs.v13.i3.pp1007-1013 | |
| dc.identifier.scopus | 2-s2.0-85063134062 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14170/10952 | |
| dc.relation.funding | Universiti Malaysia Perlis | |
| dc.relation.grantno | undefined | |
| dc.relation.ispartof | Indonesian Journal of Electrical Engineering and Computer Science | |
| dc.relation.ispartofseries | Indonesian Journal of Electrical Engineering and Computer Science | |
| dc.relation.issn | 25024752 | |
| dc.rights | open access | |
| dc.subject | Dickson Multiplier | Energy Harvesting | Stub Matching | |
| dc.title | Rectifier for RF energy harvesting using stub matching | |
| dc.type | Journal | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 1013 | |
| oaire.citation.issue | 3 | |
| oaire.citation.startPage | 1007 | |
| oaire.citation.volume | 13 | |
| oairecerif.affiliation.orgunit | Bioelectromagnetics Research Group (BioEM) | |
| oairecerif.affiliation.orgunit | Universiti Malaysia | |
| oairecerif.affiliation.orgunit | Universiti Malaysia | |
| oairecerif.affiliation.orgunit | Universiti Kuala Lumpur | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| person.identifier.scopus-author-id | 26428028100 | |
| person.identifier.scopus-author-id | 57210314287 | |
| person.identifier.scopus-author-id | 57207882127 | |
| person.identifier.scopus-author-id | 36193240000 |