Publication:
The Water Based Photovoltaic Thermal Fiberglass Collector: An Experimental Investigation

cris.author.scopus-author-id 57219421621
cris.author.scopus-author-id 57195432490
cris.author.scopus-author-id 7003375391
cris.author.scopus-author-id 57210767098
cris.author.scopus-author-id 7801686246
dc.contributor.author Mustafa W.
dc.contributor.author Fudholi A.
dc.contributor.author Sopian K.
dc.contributor.author Mustapha M.
dc.contributor.author Ahmudiarto Y.
dc.date.accessioned 2024-09-29T00:53:46Z
dc.date.available 2024-09-29T00:53:46Z
dc.date.issued 2021-12-01
dc.description.abstract The increase in ambient and surface temperatures is one of the main factors that lead to the decrease in the output power and efficiency of photovoltaic panels. A thermal photovoltaic collector (PVT) system is a method introduced to overcome the problem of excess heat on photovoltaic panels. As a result, in addition to the cooling method, many other collector designs have been widely developed to improve the cooling rate and heat transfer between the photovoltaic module and the working fluid. The purpose of this study was to introduce and evaluate a fiberglass collector design in a laboratory environment with varying solar radiations, using water as the working fluid. The thermal and electrical performances of the PVT collector were determined under solar simulator radiation between 450–850 W/m2. Experiments were conducted at each solar simulator with flow rate adjustment between 1.4-3 l/min. Electrical properties such as voltage, current, output power, efficiency, and thermal efficiency will be evaluated throughout the experiment. Experiments revealed that the design of this fiberglass collector is capable of increasing the output power and achieving the highest thermal efficiency of 72.98%, a temperature reduction rate of 35.36%, with a flow rate of 3l/min at 850 W/m2. This fiberglass collector produces a total efficiency equivalent of 82.68%, an electrical efficiency of 9.7%, and thermal efficiency of 72.98%. Aside from the demonstrated ability of the cooling method for improving the performance of PVT collectors, this collector is also simple to fabricate and inexpensive to manufacture.
dc.identifier.scopus 2-s2.0-85123886135
dc.identifier.uri https://hdl.handle.net/20.500.14170/5911
dc.relation.grantno undefined
dc.relation.ispartof International Journal of Renewable Energy Research
dc.relation.ispartofseries International Journal of Renewable Energy Research
dc.subject Fiberglass collector | photovoltaic module efficiency | photovoltaic thermal (PVT) | thermal performance
dc.title The Water Based Photovoltaic Thermal Fiberglass Collector: An Experimental Investigation
dc.type Journal
dspace.entity.type Publication
oaire.citation.endPage 1672
oaire.citation.issue 4
oaire.citation.startPage 1663
oaire.citation.volume 11
oairecerif.affiliation.orgunit Universiti Kuala Lumpur
oairecerif.affiliation.orgunit Universiti Kebangsaan Malaysia
oairecerif.affiliation.orgunit Universiti Kebangsaan Malaysia
oairecerif.affiliation.orgunit Universiti Kebangsaan Malaysia
oairecerif.affiliation.orgunit Lembaga Ilmu Pengetahuan Indonesia
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.scopus-author-id 57219421621
person.identifier.scopus-author-id 57195432490
person.identifier.scopus-author-id 7003375391
person.identifier.scopus-author-id 57210767098
person.identifier.scopus-author-id 7801686246
Files