Publication:
Develop Portable Blood Analyzer Based on Temperature and Quantity Level

cris.author.scopus-author-id 57221205870
cris.author.scopus-author-id 57219421621
cris.author.scopus-author-id 56479160600
cris.author.scopus-author-id 55050201000
cris.author.scopus-author-id 55831869200
cris.author.scopus-author-id 56239489400
cris.virtual.department Universiti Malaysia Perlis
cris.virtual.department Universiti Malaysia Perlis
cris.virtualsource.department 8b866d4d-5b85-4c62-a68b-757698ef8d83
cris.virtualsource.department 9e552ad3-a7b9-4add-93e9-db1efcd610c1
dc.contributor.author Farhan Sukemi M.A.
dc.contributor.author Wan Azani Wan Mustafa
dc.contributor.author Aihsan M.Z.
dc.contributor.author Zol Bahri Razali
dc.contributor.author Akhmal S.
dc.contributor.author Saidi S.A.
dc.date.accessioned 2024-10-01T07:11:21Z
dc.date.available 2024-10-01T07:11:21Z
dc.date.issued 2020-12-18
dc.description.abstract This technical paper presents a developing portable blood analyzer for monitoring of human blood sample. Perseverance of blood sample in hospitals is important in order to obtain a great quality of blood and therefore it able to determining the human type of disease. This is a life-threatening early step in most medical applications fields such as diagnosis, treatment and medical research. The proposed system consists of three main parts. In the first part, the use of convenient and handy device to deal with the problem of incorrect temperature value and inadequate quantity of blood sample. Most of previous human hospitality services show a fail to handle and properly in time to take human blood sample for diagnosis in a schedule time frame such as not punctual in taking blood sample from a patient in three different times in one day. The consequences is that these blood sample are not in perfect quality for a correct estimation of the human disease towards a pathology unit. The proposed method is a device that uses infrared temperature system and non-contact blood sample quantity detection. In the second part is by combining those two approaches to single programmable electronic modules that are used to minimize the size of the portable device in the resulting techniques to improve the functionality. The third part is accomplished by using a modern technique to produce an interface to provide the value of human blood sample and shows it on display for monitoring purposes. The programmable coding has been test in several different types of sensors and physical part. The experimental results show that this method able to integrate both requirement of human blood sample perseverance with a contactless method towards a blood tube, providing the output value of quality characteristic in a display and making it well-suited for a convenient practical application system. The experimental results in real time applications shows the effectiveness, reliable and efficiency in the proposed approach which able to almost accurately detect and monitor the human blood sample with the ability to detect different types of people gender and blood type. The proposed coding system can be executed at more precise time scheduling which is better than real life human monitoring system.
dc.identifier.doi 10.1088/1757-899X/932/1/012057
dc.identifier.scopus 2-s2.0-85098502002
dc.identifier.uri https://hdl.handle.net/20.500.14170/7425
dc.language.iso en
dc.relation.grantno undefined
dc.relation.ispartof IOP Conference Series: Materials Science and Engineering
dc.relation.ispartofseries IOP Conference Series: Materials Science and Engineering
dc.relation.issn 17578981
dc.rights open access
dc.title Develop Portable Blood Analyzer Based on Temperature and Quantity Level
dc.type Conference Proceeding
dspace.entity.type Publication
oaire.citation.issue 1
oaire.citation.volume 932
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.citation.number 012057
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.scopus-author-id 57221205870
person.identifier.scopus-author-id 57219421621
person.identifier.scopus-author-id 56479160600
person.identifier.scopus-author-id 55050201000
person.identifier.scopus-author-id 55831869200
person.identifier.scopus-author-id 56239489400
Files