Publication:
Two stage CMOS operational amplifier in 0.13?μm technology using pseudo cascode compensation

cris.author.scopus-author-id 57205130853
cris.author.scopus-author-id 57201669864
cris.author.scopus-author-id 57189034221
cris.author.scopus-author-id 35090423100
dc.contributor.author Cheah H.T.
dc.contributor.author Ahmad N.
dc.contributor.author Othman N.
dc.contributor.author Sabki S.N.
dc.date.accessioned 2025-01-13T10:15:37Z
dc.date.available 2025-01-13T10:15:37Z
dc.date.issued 2018-12-06
dc.description.abstract Various wireless, implantable and wearable devices are used for continuous monitoring of health condition. These devices consist of various type of biosensor such as pacemaker. The operational amplifier (op-amp) is an example of an extended device which is located at the front end of this biosensor. The op-amp plays an important role of amplifying the strength of a signal. This paper focuses on the development of a two stage CMOS op-amp in 0.13?μm technology using pseudo cascode compensation technique. The pseudo cascode compensation technology is proposed to enhance the stability of a circuit. The op-amp is implemented using 0.13?μm CMOS technology from Siltera (Malaysia) and is simulated using a Mentor Graphic Design Architect software package. The proposed op amp achieved DC gain of 57.87?dB, unity gain frequency of 57.390?kHz, bandwidth of 54.87?Hz and power dissipation of 3.02?mW for 50?μA external bias current. The op-amp shows exceptionally stable operation with phase margin of 80.65 ° and gain margin of 10.901?dB.
dc.identifier.doi 10.1063/1.5080896
dc.identifier.isbn [9780735417717]
dc.identifier.scopus 2-s2.0-85058692656
dc.identifier.uri https://hdl.handle.net/20.500.14170/12559
dc.relation.grantno undefined
dc.relation.ispartof AIP Conference Proceedings
dc.relation.ispartofseries AIP Conference Proceedings
dc.relation.issn 0094243X
dc.rights open access
dc.title Two stage CMOS operational amplifier in 0.13?μm technology using pseudo cascode compensation
dc.type Conference Proceeding
dspace.entity.type Publication
oaire.citation.volume 2045
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.citation.number 020083
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.scopus-author-id 57205130853
person.identifier.scopus-author-id 57201669864
person.identifier.scopus-author-id 57189034221
person.identifier.scopus-author-id 35090423100
Files