Publication:
Polymer-tethered metal oxide sensing surface for abdominal aortic aneurysm biomarker quantification by dual antibodies

cris.author.scopus-author-id 57016076700
cris.author.scopus-author-id 55939969300
cris.author.scopus-author-id 56953702600
cris.author.scopus-author-id 57216902201
cris.author.scopus-author-id 7006558013
cris.author.scopus-author-id 55654521800
cris.author.scopus-author-id 57204457340
cris.virtual.department Universiti Malaysia Perlis
cris.virtualsource.department 3f983c2e-28f9-4f7e-9c19-b081a6c20fd8
dc.contributor.author Hong X.
dc.contributor.author Hong X.
dc.contributor.author Zhao H.
dc.contributor.author Shi Q.
dc.contributor.author Subash Chandra Bose Gopinath
dc.contributor.author Lakshmipriya T.
dc.contributor.author Yan G.
dc.date.accessioned 2024-10-03T23:56:38Z
dc.date.available 2024-10-03T23:56:38Z
dc.date.issued 2021-03-01
dc.description.abstract An abdominal aortic aneurysm (AAA) is caused by a vascular disease and results in the presence of a bulged portion (>5.5 cm) of the aorta in the abdominal area, which can rupture due to high blood pressure. Imaging techniques are broadly used to diagnose AAA and provide supporting evidence for treating the patient. Insulin-like growth factor 1 (IGF1) is a well-known biomarker for AAAs and helps to identify the severity of the disease. In this research, IGF1 was detected by dual antibodies (mono- and polyclonal) on gap-fingered (~50 µm) interdigitated dielectrode (IDE) metal oxide surfaces (5 × 6 mm). The hydroxylated IDE surface was coated with silane-PEG-COOH to reduce biofouling and improve detection. IGF1 at 1 pM (y = 1.641x-1.605; R²=0.9826) was determined to have a low detection limit by a monoclonal antibody (200 nM); the detection limit was further improved to 100 fM (y = 10.12x-3.6966; R²=0.9631) in a 10-fold increment by employing dual antibodies with low-femtomolar sensitivity. Moreover, the current responses were found to increase greatly due to this sandwich pattern at dose-dependent concentrations from 100 fM to 1 nM. Control experiments with IGF2 and IGFBP3 (1 nM) showed minor variations in current changes, indicating the specific detection of IGF1. This method employing dual antibodies on the dielectrode surface helps identify AAAs and their progression.
dc.identifier.doi 10.1016/j.jtice.2021.03.013
dc.identifier.scopus 2-s2.0-85104062103
dc.identifier.uri https://hdl.handle.net/20.500.14170/9124
dc.language.iso en
dc.relation.funding Universiti Malaysia Perlis
dc.relation.grantno undefined
dc.relation.ispartof Journal of the Taiwan Institute of Chemical Engineers
dc.relation.ispartofseries Journal of the Taiwan Institute of Chemical Engineers
dc.relation.issn 18761070
dc.subject Insulin-like growth factor | Interdigitated electrode sensor | Sandwich assay | Silane-PEG-COOH | Silica
dc.title Polymer-tethered metal oxide sensing surface for abdominal aortic aneurysm biomarker quantification by dual antibodies
dc.type Journal
dspace.entity.type Publication
oaire.citation.endPage 48
oaire.citation.startPage 43
oaire.citation.volume 120
oairecerif.affiliation.orgunit China-Japan Union Hospital of Jilin University
oairecerif.affiliation.orgunit China-Japan Union Hospital of Jilin University
oairecerif.affiliation.orgunit China-Japan Union Hospital of Jilin University
oairecerif.affiliation.orgunit China-Japan Union Hospital of Jilin University
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit Universiti Malaysia Perlis
oairecerif.affiliation.orgunit China-Japan Union Hospital of Jilin University
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation Universiti Malaysia Perlis
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.orcid #PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.scopus-author-id 57016076700
person.identifier.scopus-author-id 55939969300
person.identifier.scopus-author-id 56953702600
person.identifier.scopus-author-id 57216902201
person.identifier.scopus-author-id 7006558013
person.identifier.scopus-author-id 55654521800
person.identifier.scopus-author-id 57204457340
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
Research repository notification.pdf
Size:
4.4 MB
Format:
Adobe Portable Document Format
Description: