Options
Wan Abdul Rahman Assyahid Wan Ibrahim
Preferred name
Wan Abdul Rahman Assyahid Wan Ibrahim
Official Name
Wan Abdul Rahman Assyahid, Wan Ibrahim
Alternative Name
Wan Abdul Rahman Assyahid, Wan Ibrahim
Wan Abd. Rahman Assyahid, Wan Ibrahim
Main Affiliation
Scopus Author ID
56943590200
Now showing
1 - 5 of 5
-
PublicationDesign and development of a cordless screwdriver: An analysis( 2021-07-21)
;Shafeeq Ahmad Shamim Ahmad ;Hashim A.H. ;Rahman A.S.A. ;Kamarul Radhi Md ZohidBalakrishnan V.The aim of this paper is to focus on some important aspects of the use of cordless screwdrivers in situations of work. Emphasizes on comfort while user uses cordless screwdriver. Descriptors of comfort in the use of hand tools have been collected from interviews. Functionality and physical interaction have been found to be the most important comfort factors in using a screwdriver. The ergonomically modified screwdriver handle provides greater operational efficiency. The findings of this research is significant in contemplating on the differences between discomfort and comfort. Cordless Screwdriver with built-in power of 3.7 kilowatts has been established. A better battery, with a voltage display, was made comfortable for consumers. In addition, the soft grip handle will allow the consumer to have a relaxed grip when using the product.10 3 -
PublicationOptimization of heating rate on hybrid microwave sintering of the PM Fe-Cr MMCs reinforced with Al2O3particleThis study reports the optimization of heating rate on the microwave sintered Fe-Cr-Al2O3 metal matrix composite (MMC). The heating rate was selected between 10°C/min to 60°C/min with increment of 10°C/min respectively. The samples were fabricated via PM route and microwave sintering was carried out in a tubular microwave furnace HAMiLab-V3 in N2 atmosphere purposely to avoid any oxidation and chemical reaction to samples. The microstructure of sintered samples was evaluated using SEM and bulk density and porosity were determined based on ASTM B962 - 17 and the microhardness were determined based on ASTM E384. The optimized heating rate of the sample was selected based on the micro hardness value and total porosity percentage as well as based on SEM microstructure analysis. The results revealed that the optimum heating rate occurred at 20°C/min due to the highest value of hardness achieved which is about 119.28 HV with at the highest bulk density about 6.07 g/cm3 and at the lowest total porosity about 14.55%. SEM micrographs also showed that the diffusion was mostly effective at 20°C/min heating rate compared to others, indicated that significant grain boundary diffusion of Fe matrix into Al2O3 particle was occurred.
5 4 -
PublicationHard-porous-lightweight PM Fe-Cr-Al2O3MMCs sintered under hybrid microwave energyThis study reports on the effect of Al2O3 particles on the density of Fe-Cr metal matrix composite (MMCs) produced through PM route then sintered under hybrid microwave energy. The sample was prepared by mixing the Al2O3 particle in 3D-tubular shaker at six different weight percentage of Fe-Cr matrix started from 5 wt.% to 30 wt.% with 5% in increment. The sintering process was performed under controlled N2 atmosphere in a tubular microwave furnace. Determination of bulk density and porosity was done according to Standard Test Method ASTM B962 - 17, while ASTM E384 was used to determine the microhardness. Assessment of the sample was based on density, porosity, hardness and microstructure evaluation. The result show that incorporating the Al2O3 particle were significantly increase the microhardness, decrease the bulk density and increase the porosity of the in Fe-Cr composite.
1 -
PublicationErgonomic study of X-L wheelchairWheelchairs have been used widely as the one of the vehicles that are designated purposely to help the disabled patient to easily move around. However, the standard wheelchairs currently available in the market are mostly fit to patients which have average size and can only accommodate the patient with maximum body mass up to 100kg. When a big size or extra-large (XL) patient with body mass more than 100 kg uses this standard wheelchair, they may feel discomfort, cramped as well as restricted movement. Furthermore, the structure of standard wheelchairs may not be safe enough to hold the load of big size patient weight. Therefore, this project is focused to study the appropriate an ergonomic body sizes and dimensions of big patients that body mass ranging from minimum 100kg to maximum 150kg. The investigation is focused on the customer needs as well as anthropometry body measurements. The data was collected from the questionnaires and direct interview among 30 personnel with the body mass in target range. The information gathered then had been used to custom design the XL wheelchair that fulfil the most requirements and having sturdy structure that safety to be used.
2 -
PublicationAnalysis of torchlight using engineering analysis tools( 2021-05-03)
;Ahmad S.A.S. ;Ting Hua Jui ;Nur Ainin Faissal ;Nurafzarini Mohd RusdiNor Syahirah Mat PiahThe objective of this paper to improve the design of the torchlight when holding the torchlight and to increase the durability of the torchlight against water by using the float materials. The torchlight also has been analysed using Design for Manufacturing Assembly (DFMA), Failure Modes and Effect Analysis (FMEA), and Sustainability Analysis in order to provide better product.1 19