Publication:
Warpage analysis with straight drilled and conformal cooling channels on front panel housing by using taguchi method

dc.contributor.editor Shayfull Zamree Abd. Rahim
dc.contributor.editor Safian Sharif
dc.contributor.editor Azlan Mohd Zain
dc.contributor.editor Rozaimi Mohd Saad
dc.contributor.editor Ahmad Fairuz Mansor
dc.date.accessioned 2025-02-18T06:38:28Z
dc.date.available 2025-02-18T06:38:28Z
dc.date.issued 2014
dc.description.abstract The challenging in injection molding process is to get the uniform thermal distribution on the molded parts during the cooling stage which is mainly depend on the design of the cooling channels in injection mold. Poor design of cooling channels will result a non-uniform thermal distribution which lead to a longer cycle time, differential shrinkage and warpage defects on the molded parts. In this study, the performance of conformal cooling channels compared to the straight drilled cooling channels in order to minimize the warpage on the front panel housing is evaluated. The simulation results from Autodesk Moldflow Insight (AMI) 2013 are analyzed by using Taguchi Method and Analysis of Variance (ANOVA). The analyses show that conformal cooling channels are able to improve the quality of the molded parts in term of warpage compared to the conventional straight drilled cooling channels and the results are beneficial for the molding industries which involving the precise parts.
dc.identifier.doi https://doi.org/10.4028/www.scientific.net/KEM.594-595.593
dc.identifier.uri http://www.ttp.net/
dc.identifier.uri http://www.scientific.net/KEM.594-595.593
dc.identifier.uri https://hdl.handle.net/20.500.14170/13672
dc.language.iso en
dc.relation.ispartof Key Engineering Materials
dc.relation.issn 1662-9795
dc.subject Analysis of Variance (ANOVA)
dc.subject Conformal cooling channel
dc.subject Injection molding process
dc.subject Straight drilled cooling channels
dc.subject Taguchi
dc.title Warpage analysis with straight drilled and conformal cooling channels on front panel housing by using taguchi method
dc.type Resource Types::text::journal::journal article
dspace.entity.type Publication
oaire.citation.endPage 603
oaire.citation.startPage 593
oaire.citation.volume 594-595
oairecerif.editor.affiliation Universiti Malaysia Perlis
oairecerif.editor.affiliation Universiti Teknologi Malaysia
oairecerif.editor.affiliation Universiti Teknologi Malaysia
oairecerif.editor.affiliation Universiti Teknologi Malaysia
oairecerif.editor.affiliation Universiti Malaysia Perlis
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
Warpage analysis with straight drilled and conformal cooling channels on front panel housing by using taguchi method.pdf
Size:
132.54 KB
Format:
Adobe Portable Document Format
Description: