PublicationSimulation of reverse power relay in 11 kV generator protection( 2021-05-03)
; ;Lee Y.Y. ;Nabipour-Afrouzi H. ;Mousa M.I. ; ;Mehranzamir K.This paper proposed the modelling and simulation of generator protection for power system using digital reverse power relay. The operations of the power plant are often interrupted by the reverse power generation. Therefore, generators need to be closely monitored and controlled. In this study, 11 kV synchronous generators are connected to 220 kV load through a step-up transformer, and a new model of reverse power relay is added for generator protection. The reverse power relay proposed in this paper is a digital relay with high accuracy and high reacting speed. Several cases based on various types of mechanical inputs to the generator were studied to test the operation of the reverse power relay. This simulation was done using MATLAB/Simulink. The results show that the 11 kV generator protection is successful with this new model reverse power relay. Besides, the simulation results were similar result compared to the theory result. From the simulation results, the integral output of the relay will reach the threshold value 'L' whenever there is a reversed power flow fault found in the system. Consequently, the relay will be triggered to provide protection for the generator. This model has been added into online resources of MATLAB Power System Tools. In addition, this model may also help the engineers to develop the analytical skills under various conditions.29 2 -
PublicationStudy of soil resistivity using wenner four pin method: Case study( 2020-12-07)
;Sazali M.S. ; ;Wong T.S. ; ;Abdul-Malek Z.Nabipour-Afrouzi H.Soil resistivity is usually measured at the selected site either for new installation or in the existing grounding system. In this paper, soil resistivity test has been done to study the soil resistivity around the 33 kV substation according to IEEE 81-1983 standard. A factory site located in Kulim Hi-tech, Malaysia has been selected to research on the soil resistivity. The soil resistance measured in this study is then be calculated in using the soil resistivity formula. The soil resistivity shows that the longer the distance between rods, the lower the resistivity of soil due to larger soil volume. The lowest soil resistivity around the substation is 3.454 Ω.m, which is on the left side of the substation with a distance of 5 meters between the rods followed by front side with 15.71 Ω.m, right side with 34.243 Ω.m and backside with 45.239 Ω.m. While the highest soil resistivity is 176.306 Ω.m on the right side of the substation with a 2-meter distance between each rod.7 21