Options
Mohamed Elshaikh Elobaid Said Ahmed
Preferred name
Mohamed Elshaikh Elobaid Said Ahmed
Official Name
Mohamed Elshaikh Elobaid , Said Ahmed
Alternative Name
Ahmed, Mohamed Elshaikh Elobaid Said
Said Ahmed, Mohamed Elshaikh Elobaid
Elobaid, Mohamed Elshaikh
Main Affiliation
Scopus Author ID
57190012447
Researcher ID
R-7502-2019
Now showing
1 - 3 of 3
-
PublicationDevelopment of Cloud-based Electronic Nose for University Laboratories Air Monitoring( 2020-12-18)
;Saad F.S.A.Ismail K.A.Indoor air in area such as house, shopping complex, hospital, university, office and hotel should be monitor for human safety and wellbeing. These closed areas are prone to harmful air pollutants i.e. allergens, smoke, mold, particles, radon and hazardous gas. Laboratories in university are special room in which workers (student, technician, teaching/research assistants, researcher and lecturer) conduct their works and experiments. These activities and the environment will generate air pollutants which concentration depending on their parameters. Anyone in the environment that exposure to these pollutants may have safety and health issue. This paper propose a study of development of a cloud-based electronic nose system for university laboratories air monitoring. The system consists of five dsPIC33-based electronic nose (e-nose) as node which measure main indoor air pollutants along with two thermal comfort variables, i.e. temperature and relative humidity. The nodes are placed at five different laboratories for acquiring air pollutants data in real time. The data will be sent to a web server and the cloud-based system will process, analyse and display by a website in real time. The system will monitor the laboratories main air pollutants and thermal comfort by forecast the contaminants concentration and dispersion in the area. In case of air hazard safety (e.g., gas spills detection and pollution monitoring), the system will alert the security by activate an alarm and through e-mail. The website will display the Air Pollution Index (API) of the area in real-time. Results show that the system performance is good and can be used to monitor the air pollution in the university laboratories. -
PublicationCloud-based System for University Laboratories Air Monitoring( 2020-09-21)
;Mustafa M.H.Indoor air such as house, shopping complex, hospital, university, office and hotel should be monitor for human safety and wellbeing. These closed areas are prone to harmful air pollutants i.e. allergens, smoke, mold, particles radon and hazardous gas. Laboratories in university are special room in which workers (student, technician, teaching/research assistants, researcher and lecturer) conduct their works and experiment. The activities and the environment will generate specific air pollutant which concentration depending to their parameters. Anyone in the environment that exposure to these pollutants may affect safety and health issue. This paper proposes a study of development of a cloud-based electronic nose system for university laboratories air monitoring. The system consists of DSP33-based electronic nose (e-nose) as nodes which measure main indoor air pollutant along with two thermal comfort variables, temperature and relative humidity. The e-noses are placed at five different laboratories for acquiring data in real time. The data will be sent to a web server and the cloud-based system will process, analyse using Neuro-Fuzzy classifier and display on a website in real time. The system will monitor the laboratories air pollutants and thermal comfort by predict the pollutant concentration and dispersion in the area i.e. Air Pollution Index (API). In case of air hazard safety (e.g., gas spills detection and pollution monitoring), the system will alert the security by activate an alarm and through e-mail. The website will display the API of the area in real-time. Results show that the system performance is good and can be used to monitor the air pollutant in the university laboratories. -
PublicationDrunken drive detection with smart ignition lock( 2021-01-01)
;Muthukarpan S.L.A. ;Rahim M.K.A.Khalib Z.I.A.Drink and drive issue have become solemnly that needs immediate attention. This is due to drivers’ ignorance towards road rules and regulations and their selfish attitude that caused loss of innocent lives. Although previously there is a drunk detecting mechanism using breathalyzer but it isn’t suitable for current fast-paced lifestyle. Therefore, to overcome these issues, this system is proposed. This system is fixed on vehicle’s steering to measure alcohol concentration reading using MQ-3 sensor from the driver’s exhaled breath. If the driver found to be drunk beyond the threshold level of 400 ppm, then ignition lock is activated and the car engine does not start till alcohol concentration falls to a safe level. Or, if the driver consumes an alcoholic drink while driving, upon exceeding permissible limit, the car slows down till it stops. Then, the location of the vehicle is tracked and sent as Google Map integrated link via text message to authorized unit. Simultaneously, the car buzzer goes off while the car slows down so that surrounding road users are aware of the driver’s condition and drives at a distance. The proposed detection system is highly potential to be implemented for reducing the drunk and drive accidents.1