    Physical behaviours of maximum loading and cracking for slurry infiltrated fibre reinforced concrete
    Concrete prisms are being test with flexural testing by different percentage volume of steel fibres. The total number of 24 prisms were made which contain 3 %, 6 % and 9 % of steel fibres respectively. This only consist experimental results. Specimens used in this study using a prism mold of 100 mm x 100 mm x 500 mm. Eighteen prisms will be added with a layer of 10 mm of steel fibre using slurry method. All of the samples were tested using flexural testing to determine the maximum loading. The highlight scope of this research is to evaluate the physical behavior of Slurry Infiltrated Fibre Reinforced Concrete in term of maximum load and cracking pattern. The results of the study were also compared with concrete without steel fibres. However, the workability of the concrete decreased as the number of steels fibre increase. The maximum load was obtained by the lowest percentage of steel fibre (3%).
  • Publication
    Physical properties of Dolomite fines as partially replacement of cement
    Since the cost of cement increases and the pollution to environment due to greenhouse effect are becoming more serious year by year, thus, dolomite fines subjected to replace the cement in concrete mix as it has lower cost compared to cement and it is obtain directly from the Earth ground without any manufactured process. Dolomite fines also shows almost similar physical and chemical properties as cement. The various replacement of cement with dolomite fines carried out in this study is 0%, 5%, 10%, 15% and 25%. The grade of concrete sample designed to be 30. The properties of concrete sample in terms of physical characteristics; slump, density and water absorption for various percentage replacement are determined in this study. In this study, it shows the dolomite fines are lightweight aggregate compared to the cement and the water absorption of is lower compare to that of the control concrete.
      2
  • Publication
    Relationship between Ultrasonic-Pulse Velocity and Compression Test for Different Grade of Concrete
    ( 2020-07-09) ;
    Choon Onn L.
    ;
    Nur Aizat Ahmad A.
    ;
    Shahidan S.
    ;
    Salwa Mohd Zuki S.
    ;
    ; ; ;
    Ultrasonic pulse velocity methods is one of the non-destructive testing methods. Commonly the compression test was used to determine the compression strength of concrete. Laboratory works had been carried out at heavy concrete laboratory to obtain the result for both non-destructive and destructive test. By using concrete cubes of sizes 100 x 100 x 100 mm and subjected to water curing for 7, 14, 21 and 28 days to obtained desire result for Ultrasonic Pulse Velocity and Compression test. Ultrasonic Pulse Velocity were initially done before the Compression test. The data obtained from each test has been evaluated and tabulated in this report. From this research, the variation between predicted strength and experimental strength for Ultrasonic Pulse Velocity testing was identified; the higher the pulse velocity, the higher the predicted strength and lower times passes by pulse velocity, the higher the predicted strength.
      13  2